Enterprise Colocation
Purpose-built facilities engineered for high-density AI workloads. 100% renewable hydroelectric power, direct-to-chip liquid cooling up to 250kW per rack, and carrier-neutral fiber connectivity from 1Gbps to 100Gbps+.
Per Rack
250kW
Deployment
90 Day
Renewable Energy
100%
US Locations
4
Infrastructure Built for
Every layer of our facilities is engineered from the ground up for high-density compute — and designed to give back more than they take. From closed-loop liquid cooling and on-site renewable energy to waste-heat recovery that powers local agriculture, our infrastructure proves that performance and environmental stewardship aren’t trade-offs.
Power
Powered by 100% renewable hydroelectric energy with dual-feed 480V/277 and 415V/240 three-phase distribution. Enterprise battery UPS systems ensure uninterrupted operation through any grid event.
- 100% Renewable Hydroelectric
- Dual-Feed 3-Phase Distribution
- Battery Backup UPS Systems
Cooling
Purpose-built for high-density AI workloads with direct-to-chip liquid cooling supporting up to 250kW per rack. Evaporative and adiabatic systems maintain optimal temperatures year-round without mechanical chillers.
- Direct to Chip Liquid Cooling
- Evaporative & Adiabatic Systems
- 250kW Per Rack Capacity
Connectivity
Multi-homed fiber connectivity with carrier-neutral facilities and diverse fiber paths. Scalable bandwidth from 1Gbps to 100Gbps+ delivers the redundancy and throughput modern AI workloads demand.
- 1Gbps — 100Gbps+ Fiber
- Carrier-Neutral Facilities
- Diverse Path Redundancy
Available Locations
Strategically positioned facilities across North America, each optimized for different workload profiles.
Eastern Washington
Brownfield
Available Now
R&D and cutting-edge deployment site. Ultra-low latency liquid cooling ecosystem powered by renewable hydro-energy.
- 10 MW Total Capacity
- Liquid Only Cooling Infrastructure
- 8,000 sq ft Facility Size
Where we validate next-gen hardware and cooling technologies before scaling across our network.
Western Montana
NextField
2026
Regenerative AI campus with closed-loop liquid cooling, on-site renewable energy, and waste-heat recovery.
- 20 MW Total Capacity
- Closed-Loop Liquid Cooling
- On-Site Renewable Energy
Built in partnership with the local community, with waste heat repurposed for agricultural and commercial use on-site.
Pennsylvania
Greenfield
2026
East Coast Hyperscale Gateway. Flexible hybrid cooling architecture offering bespoke high-density solutions.
- 30 MW Total Capacity
- Air or Liquid Cooling Options
- Flexible Design to Spec
Oregon
Brownfield
Available Now
Pacific Efficiency Node. Rapid deployment air-cooled facility optimized for immediate high-throughput workloads.
- 6 MW Total Capacity
- Air Cooling Only
- Immediate Deployment
Expanding Pipeline
Western Montana
2026
100 MW — 3,300 Acres — Brownfield Redevelopment
Northeast Ohio
2026
299 MW — 21.5 Acres — NextField
Central Illinois
2026
400 MW — 3,300 Acres — Greenfield
Central Alberta
2026
18.5 MW — 3 Acres — Adaptive Reuse
Southeast Alberta
2026
95.7 MW — 80 Acres — Greenfield
Southern Alberta
2026
200 MW — 468 Acres — NG + Solar
Remote Hands
On-demand 24×7 data center technicians available to all colocation customers.
Cabling & Wiring
Cross-connect termination, cable dressing, fiber light readings, and signal verification.
Rack & Stack
Equipment racking, shipping and receiving, inventory management, and vendor escort services.
Device Management
Component swaps, power resets, PDU operations, and remote troubleshooting assistance.
| Tier | Availability | Dispatch | Rate |
| Standard | Mon–Fri (8–5 PT) | 4 Hours | Contact Us |
| After Hours | 24×7 (as-available) | 2 Hours | Contact Us |
| Emergency | 24×7 (guaranteed) | ≤ 1 Hour | Contact Us |
Ready to Scale Your Infrastructure?
Whether you need GPU clusters, colocation, or custom server solutions — our team is ready to help design the perfect infrastructure for your needs.